To automate the on/off control of an Accu-Lube applicator add a solenoid valve to the air supply inside the applicator box. The parts needed are a solenoid valve and a close nipple. The solenoid valve is available in different voltages depending on your needs. Step #1 on the solenoid valve base the 1/4" NPT ports are numbered. Connect the 1/4" NPT close nipple to port #1. As with all air fitting connections it is recommended that you use Teflon tape or some other type of pipe sealant.
Step #2 open the back door of the applicator by loosening the screw in the back of the box allowing the rear door to swing open.
Step #3 remove the male run T fitting from the bulkhead fitting with a 9/16" wrench.
Step #4 loosen the lock nut on the bulkhead fitting inside the box to allow the filter assembly to rotate freely.
Step #5 insert the solenoid with the 1/4" NPT close nipple into the center of the bulk head then insert the male run T into port # 2 on the base of the solenoid valve then tighten the whole assembly turning to the point where the filter and solenoid are in the same up/down orientation.
Step #6 tighten the lock nut on the bulk head.
Step #7 reinsert the tubes into the press lock fittings.
Step #8 have a qualified electrician connect the solenoid to the desired source power. The valve will open and allow air to flow when energized. Step #9 remove the manual on/off valve from the input side of the filter/regulator and connect the air supply directly to the filter/regulator input.